Manufacturing and installation of iron free aluminum sulfate equipment and detection method for precipitated barium sulfate。-汽车-www.liusuanlvshebei.com
Release date:2023/9/19 9:35:27 Number of views:
Particle diameter distribution: The manufacturing and installation of iron free aluminum sulfate equipment is selected based on the particle distribution of the GSL-101b i laser.
Uniform menstruation: The distribution of grain diameter primarily comes from uniform values.
Surface area ratio: obtained through the conversion of uniform particle diameter, usually indicated in relative area units of 1g powder.
325 Mesh residue: This detection method primarily involves filtering 1000 grams of the sample into the endosulfan mesh of the 325 Mesh. The residue share calculated from the manufacturing and installation of the iron free aluminum sulfate equipment is the residue.
False specific gravity: This detection method involves placing 50g of the sample into a 100cc measuring cylinder and obtaining 150 values dropped from a height of 5cm.
Whiteness: measured by standard value.
PH value: An accurate PHS-3C instrument used for identifying pH values.
Oil absorption: Use JLS-K5101 method to add flaxseed titration during the inspection process until it becomes larger, and then record the data. If you have any other questions, please refer to the official website for the manufacturing and installation of non-ferrous aluminum sulfate equipment or contact us directly.
Particle diameter distribution: The manufacturing and installation of iron free aluminum sulfate equipment is selected based on the particle distribution of the GSL-101b i laser.
Uniform menstruation: The distribution of grain diameter primarily comes from uniform values.
Surface area ratio: obtained through the conversion of uniform particle diameter, usually indicated in relative area units of 1g powder.
325 Mesh residue: This detection method primarily involves filtering 1000 grams of the sample into the endosulfan mesh of the 325 Mesh. The residue share calculated from the manufacturing and installation of the iron free aluminum sulfate equipment is the residue.
False specific gravity: This detection method involves placing 50g of the sample into a 100cc measuring cylinder and obtaining 150 values dropped from a height of 5cm.
Whiteness: measured by standard value.
PH value: An accurate PHS-3C instrument used for identifying pH values.
Oil absorption: Use JLS-K5101 method to add flaxseed titration during the inspection process until it becomes larger, and then record the data. If you have any other questions, please refer to the official website for the manufacturing and installation of non-ferrous aluminum sulfate equipment or contact us directly.